Precision & Air Handling.
Data centers and pharmaceutical labs require more than just cooling; they require absolute precision in humidity and temperature stability. Our range of Precision Air Conditioners (PAC) and AHUs provide the exact environmental parameters needed to protect critical infrastructure and sensitive manufacturing processes.
Precision Air Conditioning (PAC/CRAC)
Essential thermal defense deployed where a single thermal spike equates to catastrophic hardware failure.
Global IT Standard
High Sensible Heat Ratio (SHR)
Operates at an SHR of 0.95 to 1.0, using nearly 100% of energy to lower temperature without removing moisture, preventing static electricity arcs.
Massive Air Volume (CFM)
PAC units utilize massive EC fans to move huge volumes of air over a cooling coil kept just above the dew point to prevent condensation.
Targeted Delivery
Forces dense, chilled air beneath a raised floor (cold aisle), injecting it directly into server intake racks.
Specified For
Telecommunications switching hubs, mainframe server rooms, and medical MRI/CT scanner suites.
Primary Usage
Engineered for 24/7/365 continuous operation in environments where hardware failure is not an option.
Custom Air Handling Units (AHUs)
The primary 'lungs' of a central plant, delivering massive volumes of conditioned air over long distances.
Custom AHU Series
Double Skin AHU
Industrial AHU
Custom Performance
Thermal Break Isolation
Uses a rigid polymer isolation inside the aluminum frame to prevent condensation and rust when handling freezing air.
Deep Coil Heat Transfer
Mixed fresh and return air is forced across deep, 8-row chilled water coils for maximum energy extraction.
High-Static Distribution
Massive centrifugal blowers push the conditioned air through complex, long-distance duct networks.
Specified For
Large corporate towers, pharmaceutical manufacturing lines, and massive commercial environments.
Primary Usage
Utilized when a facility requires massive volumes of deeply filtered, highly conditioned air.
Fan Coil Units (FCUs)
Rapid, localized comfort and individual temperature control for rooms tied to a massive central plant.
Horizontal / Vertical FCU
Commercial FCU
Chilled Water FCU
Precision Series
Decentralized Chilling
Small, localized units containing a cooling coil and a fan are installed directly in individual rooms.
Wireless Thermostatic Control
Utilizes advanced SRJ03 wireless controls to detect localized heat spikes and adjust comfort levels.
Motorized Modulation
A motorized valve allows central plant chilled water into the FCU coil, where the fan blows room air across it for instant cooling.
Specified For
Individual hotel suites, hospital patient rooms, and enclosed executive office cabins.
Primary Usage
Eliminates the need for massive VAV ductwork while providing individual control to occupants.